Electric migration
Description:
Corrosion (corrosion trees) due to electric migration between conductors with diverging electric potential (notice direction of migration). This defect is due to environmental stress (noxious gases, humidity) in combination with different potentials at uncovered or not sufficiently covered conductors.
Causes/Remedy:
- lack of solder resist
- defective solder resist
- environmental stress unaccounted for

visual, optical inspection - general view
Description:
Detailed view of context described before. Typical corrosion tree indicating migration of conductive material.
Causes/Remedy:
- lack of solder resist
- defective solder resist
- environmental stress unaccounted for

visual, optical inspection - general view
Black tarnished contact areas
Description:
Black tarnished and uncovered contact areas of a PCB. The surface finish used in this case (NiAu) entered into reaction with the environmental conditions. Corrosion of this kind does not allow solder joints any more. Not acceptable. These PCBs must not be used.
Causes/Remedy:
- storage of PCB in noxious gas atmosphere
- best before time exceeded
- deficiencies in surface finish

visual, optical inspection - general view
Our analytics team can help you find the cause.
go to failure analysis at TechnoLab